1.) The NVRmini only can send one system alarm to CMS.
- Abnormal disk status
2.) The Main Console can send the four system event alarm to CMS.
- Disk Space Exhausted
- System Health Unusual
- Resource Depleted
- Network Congestion
Environment
Model :
- MainConsole, NVRmini and NVRmini2
Version :
- MainConsole:v3.5.20
- NVRmini:FW v2.8
- NVRmini2:FW v1.3
Settings
A.) Setup alarm in NVRmini & NVRmini2 and send to the CMS.
Example, NVRmini send the Abnormal Disk Status Alarm to CMS
1.) Go to “Setting→Recording→Event&Action Management” page.
2.) Check the “System→Abnormal disk Status”.
3.) Click “Add” button and select the “CMS”.
4.) Open “NCS Client”.
5.) Enable the “Edit Mode”.
6.) Right click on “Alarm” and add a “New Alarm”.
7.) Check the your “NVRmini” in the Source Device list, and check the “System Disk Abnormal” in Event Message list.
B.) Setup alarm in MainConsole and send to the CMS.
Example, MainConsole send the System Alarm to CMS
1.) Click “Smartguard Configuration” button.
2.) Select “System”, and right click and select “New”.
3.) Choose “Event Type”.
4.) Click “Add” button, and select the “Central Server”.
5.) Open “NCS Client”.
6.) Enable the “Edit Mode”.
7.) Right click on “Alarm” and add a “New Alarm”.
8.) Check the your “MainConsole” in the Source Device list, and check the “Disk Space Exhausted, System Health Unusual, Resource Failure and Network Abnormal” in Event Message list.